5.1.11 AGING
Outline
For the durability testing, continuous reciprocating operation is executed.
List of AGING items
*It may cause ink leakage from the Head when executed in keeping the ink charged.
Name of Test Function
XY SERVO* Continuous reciprocating operation in X-axis and Y-axis
X SERVO Continuous reciprocating operation in X-axis
Y SERVO* Continuous reciprocating operation in Y-axis
PUMP MOTOR Continuous operation of Ink-supplying Pump Motor (Max.24Days)
WIPER MOTER Continuous reciprocating operation of Wiper Motor (Max.9999Times)
WIPE HEAD Continuous reciprocating operation of Wiping. (Max.9999Times)
CAPPING Continuous reciprocating operation of Capping.
CLEANING Execution of cleaning operation by the designated times (Max.500Times)
FLASHING Continuous reciprocating operation of Flashing.
X measure Continuous operation of the X measure.
COM For developmental debugging
CIRCURATION Operation of Circulation Pump Motor. (Not used for 150 series)
CARTRIDGE VALVE Operation of Cartridge valve.
ノズルケン
Continuous reciprocating operation of Nozzle detecting unit. (Not used for 150 series)
TEST FEED Continuous reciprocating operation of quantity of designated field.
For the work, put down unused media or the like in advance since it may cause ink leakage when
[Y SERVO] or [XY SERVO] is executed.
MAINTENANCE MANUAL > Test Items > Test Function > AGING
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0