© 2014 MIMAKI ENGINEERING CO.,LTD.
3.4.2 P.1
1
2
3
4
5
6
7
8
R.1.0
MAINTENANCE MANUAL > Workflow > Cutting Related Parts > Replacement of the Mark Assy
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver. Remark
1.0
3.4.2 Replacement of the Mark Assy
List of replacement procedures
Item Work operation Description Ref.
Covers
1.
Removal of covers, etc. Remove the C head cover. 6.1.1
Mark Assy
2.
Removal of the pen assy. 6.6.2
3.
Removal of the mark assy. Remove the mark assy. 6.6.3
4.
Mounting of the mark assy. Mount the mark assy.
Set the pressure of all the clamps to Middle, and clamp the
assy. Then adjust so that the assy is positioned 2.5 mm above
the platen on the right station side.
6.6.3
5.
Mounting of the pen assy. Mount the pen assy. 6.6.2
Adjustment
6.
Adjustment of the pen stroke. Adjust so that the pen stroke is 5 ±0.2 mm as measured from
the pen point.
7.
Adjustment of the photo sensor Adjust the [#ADJUST] - [#PHOTO SENSOR]. 4.2.22
9.
Adjustment of pen pressure Adjust the [PEN PRESSURE]. 4.2.21
10.
Pointer offset
11.
Print / Cut
Check
12.
Check each performance Check the [CUT PATTERN] and cutting position. Carry out
“print & cut” online to confirm no misalignment is found.
Covers
13.
Mounting of the covers Mount the covers that have been removed.
In installation, pay attention to harness treatment.
6.1.1
Once the S guide is removed, reinstall it while pushing the solenoid outward.