© 2014 MIMAKI ENGINEERING CO.,LTD. 6.3.1 P.1
1
2
3
4
5
6
7
8
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > X-axis Motor Assy
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0
6.3.1 X-axis Motor Assy
Work procedures
1. Remove the Cover L.
2. Remove the screws (x2) attached to the XM bracket.
3. Remove the X-axis motor connector.
4. Remove the Spring, and remove the XM bracket and X-axis
motor from the main unit.
5. Remove the screws (x3) attached to the XM bracket, and
remove the Belt and the X-axis motor Assy.
6. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
X-axis motor Assy.
XM bracketRemove spring
Connector
X-axis motor Assy.
XM bracke
t
Remove belt
The belt tension does not need to be adjusted.
R.1.0