6.4.2 COM16 IO / COM32 IO PCB Assy
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the power unit box cover.
3. Disconnect all connectors on PCB.
4. Remove the screws (x9) and then remove the COM16 IO PCB
assy. (installed for 150 series) or COM32 IO PCB assy.
(installed for 300 series)
5. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15 minutes
before restarting the operation. It is very dangerous if sleep mode functions mistakenly during the
operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of the power supply PCB assy. Take care to avoid contact with it.
COM32 IO PCB Assy
Screw
R.1.0