© 2014 MIMAKI ENGINEERING CO.,LTD. 5.1.20 P.2
5.1.20 NCU
1
2
3
4
5
6
7
8
If this is not satisfactory, loosen the adjusting screw’s nut and
turn the adjusting screw to adjust to inside the prescribed limit
(no more than 5).
Discharge position
6. Select [POS ADJ].
[]/[]: Select
[ENTER]: Confirmation
Press [ENTER] key.
7. Change display with [ENTER] key.
Not change the numerical values.
The numerals indicate, in left-to-right order: Head1
upper nozzle, Head1 lower nozzle, Head2 upper
nozzle, Head2 lower nozzle.
Unit is [0.1mm]. (ex. -7=-0.7mm)
・The numerals indicate offset value on the basis of
ideal attachment position (= mechanical design value)
of the NCU.
・Negative value indicate gap to the cap direction, posi-
tive value indicate gap to the platen.
・Position of the NCU is parallel to the head so that dif-
ference of each value is small,
Used nozzle for test:
0-24 and 156-180 nozzles of the Head 1 A line
0-24 and 156-180 nozzles of the Head 2 A line
*Nozzle missing at used nozzle does not occurred
during operation.
CHECKLIGHTVOL
=32
WIDTH
=26
SHOTPOSITION(0.1mm)
=‑8
SHOTPOSITION(0.1mm)
=‑8
Head1
Head2
R.1.0
MAINTENANCE MANUAL > Test Items > Test Function > NCU
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0