© 2014 MIMAKI ENGINEERING CO.,LTD. 5.1.20 P.3
5.1.20 NCU
1
2
3
4
5
6
7
8
8. Press [ENTER] key.
9. Confirm two numbers (
① and ① ' ) in the left figure.
Non-999 is alright. (ex. -6. -7. 999. 999)
#NCU
START [ENT]
#NCU
999.999.999.999
Confirm 2 numbers
・Non-999 is OK
① ① '
In case of 150 series (one head machine);
Confirm only ① because only ① is performed scan-
ning (display of ① ' is not changed).
The numerals indicate, in left-to-right order: Head1
, Head2, -, -.
Unit is [0.1mm]. (ex. -6=-0.6mm)
・The numerals indicate offset value on the basis of
ideal attachment position (= mechanical design value)
of the NCU.
・
Used nozzle for test:
All nozzles of the Head 1 A line
All nozzles of the Head 2 A line
*Nozzle missing at used nozzle does not occurred
during operation.
R.1.0
MAINTENANCE MANUAL > Test Items > Test Function > NCU
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0