4.2.22 P.2
4.2.22 400 mm SQUARE
1
2
3
4
5
6
7
8
8. Input the compensation value of the B-direction.
[]/[]: Compensation value input
(-6.0~ 6.0: 0.1 mm unit)
[]: Back
[ENTER]: Register/To next
9. Input the right-angle compensation value.
[]/[]: Compensation value input (0.05 mm unit)
[ENTER]: Register
10. After registered, end by the [END] key.
Remarks: How to check the right-angle accuracy in the field
The procedure checking the right-angle accuracy without a section paper is described in the following.
Use the media, which is transparent at bending even when drawn by a pen having thin tip.
1. Draw the pattern.
2. Double over the pattern at the center of reference line so that the
reference line (the paper edge in the A-axis) is overlapped.
3. Measure the upper and lower displacement of paper corner from
the B-axis.
#400mmSQUARE
dA=0.1 dB=0.3
Right-angle
compensation value
+ input
– input
Plotted line
Actual right angle line
#400mmSQUARE
ANGLEadj. = 0.05
Reference line
Two times the
right-angle
compensation
value
Center
0.2 mm
or less
0.2 mm
or less
Double over the pattern at
the center so that the upper
and lower reference line are
overlapped each other.
At shipping, the value has been compensated to 0.2
mm or less per 400 mm.
1mm 1mm
Example
Input
+0.5mm
Input
–0.5mm
R.1.0
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > 400 mm SQUARE
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver. Remark
1.0