© 2014 MIMAKI ENGINEERING CO.,LTD. 6.2.7 P.2
6.2.7 Circulation Filter
1
2
3
4
5
6
7
8
3. Remove the Circulation filter by releasing the stopper.
4. Reverse the disassembly procedure for reassembly.
Work procedure of air purge in the filter after replacement.
1. Select [#ADJUST]-[FILTER REPLACE]
Press [ENTER] key.
2. Check the amount of the waste ink, and discard as required it
appropriately.
3. Perform ink refilling after air discharging.
After that, perform cleaning automatically, and then operation is
finished.
Push claw
Circulation Filter x2
If reinserting the tube, cut about 5 mm from the tube
tip before reusing it.
#ADJUST
FILTER REPLACE [ENT]
#FILTER REPLACE
COMPLETED [ENT]
Check waste ink
level:xx%(xxxL)
#FILTER REPLACE
FILL UP [ENT]
** FILL UP **
PLEASE WAIT
CLEANING
Indicated that waste ink
amount is over 50%
#ADJUST
FILTER REPLACE [ENT]
Air purge / ink refilling
Hard cleaning
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Ink-related Parts > Circulation Filter
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.00
Remark
1.0