Error message Cause Corrective measure
The positive pressure cannot be kept
properly.
Turn off the power to the device an
turn it on after a while.
If the same error message appears
again on the LCD, contact your local
distributor to call for service.
The value of the negative pressure
sensor is abnormal.
The value of the positive pressure
sensor is abnormal.
The fluid level monitoring board is not
connected.
Ink remains too low to route the ink for
ink filling or the head cleaning.
Replace with the cartridge that has not
yet become "ink near end" and then
perform Subtank maintenance.
(P.4-15)
Runs out of ink during drawing.
Replace with the cartridge that has not
yet become "ink near end".
The float has been attached to the
upper surface of the Subtank during
discharging.
Perform Subtank maintenance
( P.4-15) or discharge again.
An error of the ink remaining control in
the tank has occurred during drawing.
Perform Subtank maintenance.
(P.4-15)
Ink in the subtank is not even.
Wait until the ink becomes even.
Tried to turn the supply pump while the
cartridge valve is closed.
Insert the usable cartridge.
Water volume is shortage.
Make sure to check the water volume.
( P.4-29)
Abnormal water tank temperature.
Turn off the power to the device an
turn it on after a while.
If the same error message appears
again on the LCD, contact your local
distributor to call for service.
Water pump timeout.
Head temperature is abnormal
condition.
The irradiation has been tried while
UV LED was in preparation.
An error occurs on the interface
between the I/F board and the control
board.
Perform a proper operation.
Head is not selected.
Select a head to be cleaned or filled.
ERROR617
POS I . PRS . KEEP LOW
ERROR618
POS I . PRS . KEEP OVER
ERROR619
NEGA . PRS . SENSOR NG
ERROR619
POSI .PRS.SENSOR NG
ERROR61a FLT CONNECT
MMMMCCCCYYYYKKKK
ERROR61b INK ROUTE
MMMMCCCCYYYYKKKK
ERROR6 1 c I NK SUPPLY
MMMMCCCCYYYYKKKK
ERROR6 1 c FLT MOT I ON
MMMMCCCCYYYYKKKK
ERROR6 1 c TNK REMA I N
MMMMCCCCYYYYKKKK
ERROR61e TANK Hi - Lo
MMMMCCCCYYYYKKKK
ERROR6 1 f
Ca t r i dge Va l ve Cl ose
ERROR705
WA T E R L ACK
ERROR705
WA T E R T ANK T EMP L OW
ERROR705
WA T E R T ANK ROU T E
ERROR705
WA T E R H E AD T EMP
ERROR706
UV NOT READY
ERROR901
OPERAT I ON
ERROR901
NO HEAD SE L EC T