Chapter 4 Maintenance
4-24
8
Press the [ENTER] key.
AIR PG.
[ENT]
START
9
Release the colored ink or the air mixed in the ink.
When you press the [ENTER] key, the machine goes into a state of atmospheric release and the
ink comes out vigorously.
Allow it to discharge until the colored ink or the air in the ink is completely gone. Thereafter, ink
without any mixed colors will be discharged.
The buzzer sound goes off at regular intervals while the ink is being discharged.
AIR PG. [DISCHARGE]
[ENT]
COMPLETED
10
Perform Step 9 for all ports from which air is purged.
The carriage may moves quickly at times. Keep your hands, head, or your body away from the
carriage.
11
Press the [ENTER] key.
AIR PG.
[ENT]
COMPLETED
12
Press the [ENTER] key.
REMOVE TOOL
[ENT]
START
13
Remove the jig and re-attach the cap.
Re-attach the cap immediately after removing the jig.
14
Once the cap is re-attached, press the [ENTER] key.
Negative pressure control restarts and wiping begins.
REMOVE TOOL
[ENT]
COMPLETED
PLEASE WAIT
15
Press to select "COMPLETED" or "RETRY".
If you select "COMPLETED" cleaning is performed. Once the cleaning is complete, proceed to
Step 18.
If you select "RETRY" the screen returns to Step 2. Select another port and perform the air purge
operation.
AIR PG.
>RETRY
COMPLETED<
16
Press the [END] key several times to end the operation.
17
Close the maintenance cover.
After the work is complete, quickly attach the removed cover. If you leave it removed for a long time,
ultra-violet rays may affect the ink.