Warning / Error Messages
5-9
1
1
1
1
5
Troubleshooting
Message Cause Solution
An error occurred in the main PCB
3.3VB power supply.
Turn off the power to the machine and turn
it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
COM driver becomes the high tempera-
ture.
New Print Head was recognized.
The main PCB Q6 is disabled (short
mode).
An error is detected on the waveform
printed on.
The machine received some data other
than command data.
Securely connect the interface cable in
position.
Use an interface cable conforming to the
specifications.
Any parameter outside the range of
acceptable numeric values was
received.
A maintenance command error
occurred.
USB device initialization failure.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Occurrence of a time out error on a
USB device.
An excessive load was applied to the X
motor.
An excessive load was applied to the Y
motor.
An error due to an excessive current of
the X motor was detected.
An error due to an excessive current of
the Y motor was detected.
ERROR 1 5 8
Ma i n PCB V3R3B
ERROR1 5 f
HEAD DR I VE HOT
ERROR 1 7 1
NEW HEAD CONNECT
ERROR 1 7 2
Ma i n PCB Q6 Ch e c k K
ERROR 1 8 6
HDC OVERF LOW
ERROR 1 8 6
HDC UNDERF LOW
ERROR 1 8 7
HDC S LEW RATE
ERROR 1 8 8
HDC MEMORY
ERROR 2 0 1
COMMAND
ERROR 2 0 2
PARAMETER
ERROR 2 0 3
Men t Command
ERROR 3 0 4
USB I N I T ERR
ERROR 3 0 5
USB T I ME OUT
ERROR 4 0 1
MOT OR X
ERROR 4 0 2
MOT OR Y
ERROR 4 0 3
X CURRENT
ERROR 4 0 4
Y CURRENT