Warning / Error Messages
5-10
SYSTEM HALT
Message Cause Solution
A HDC position counter error occurred.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Y-origin could not be detected.
Abnormal linear scale.
The X origin could not be detected.
The media is set outside the proper
area.
Check the media set position. ( P.2-5)
There remains received data that has
not yet been printed.
Execute the data clear function. ( P.2-
35)
The number of mounted heads indi-
cates 0.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The ambient temperature is out of the
usable temperature range (too low).
Adjust the ambient temperature of the
installation place.
The ambient temperature is out of the
usable temperature range (too high).
Message Solution
Turn off the main power to the machine and turn it on after a while.
Check the number and contact your local distributor to call for service. (“000” is the error
No.)
ERROR 5 0 9
HDC POSCNT
ERROR 5 0 a
YORIGIN
ERROR 5 0 f
L-SCALE BLACK
ERROR 5 1 0
XORIGIN
ERROR 5 1 6
MED I A SET POS I T I ON R
ERROR 9 0 2
DATA REMA I N
ERROR 9 0 d
NO HEAD SE L ECT
ERROR 9 1 0
ENV I RONMENT TEMP ( LO )
ERROR 9 1 1
ENV I RONMENT TEMP ( H I )
SYSTEM HALT
00 0 : MESSAGE