Troubleshooting
5-3
1
1
1
1
5
Troubleshooting
Media get jammed / media is soiled
Media jamming or stained media is considered to be due to the use of an unsuitable media or improper setting
of media.
If the media gets clogged, perform the work below:
[HEAT] or [CONSTANT] LED does not light up
Check the basic operation.
Is a recommended media used ? Use recommended media.
Is the media not curled or bent ends ? Avoid using any media with curls or bent ends.
Yes
Is the media hanging down along the platen
?
Use a take-up device ( P.2-16 step 19) or
re-load the media on the machine. ( P.2-5)
Open the front cover and
raise the clamp lever.
Remove the clogged media.
Close the front cover and
press the key.
Is the power to the machine ON ? Turn on the power to the machine. ( P.2-3)
Yes
Is the heater temperature setting effective ? Set the heater temperature. ( P.2-28)