3-4
Setting Heater
Set the heater temperature (PRE/PRINT/ POST).
1
Press the key in LOCAL.
2
Press the key.
3
Press to select [HEATER].
4
Press the key.
The set heater selection screen appears.
5
Press to select [MEDIA HEATER].
6
Press the key.
The PRINT heater temperature setting screen appears.
7
Press to set the temperature of PRE heater
(20°C to 60°C).
8
Press the key.
The PRINT heater temperature setting screen appears.
9
Press to set the temperature of PRINT
heater (20°C to 60°C).
10
Press the key.
The POST heater temperature setting screen appears.
11
Press to set the temperature of POST
heater (20°C to 70°C).
12
Press the key.
13
Press the key several times to end the setting.
You can change the heater temperature by pressing the key. ( P.2-28)