EasyManua.ls Logo

MIMAKI UJV500-160 - Preparing for the Heaters; Changing the Temperature Settings for the Heaters; Checking the Heater Temperature

MIMAKI UJV500-160
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-28
Preparing for the Heaters
Changing the Temperature Settings for the Heaters
Set the heater temperature.
Depending on the media and the profile to use, set the heater temperature.
It may take several minutes to tens of minutes for the set temperature to be reached, depending on the ambient
temperature.
1
Press the key.
2
Press the key.
3
Press to set the temperature of
each heater.
Heater selecting : Select with
Temperature setting : Set with
The heater starts to get hot.(The [HEAT] lamp lights in orange.)
When the heater temperature reaches the set temperature, the
[HEAT] lamp goes off and the [CONSTANT] lamp lights in green.
4
Press the key to end the setting.
Checking the Heater Temperature
1
Press the key.
The current heater temperature is displayed.
2
Press the key at the end of confirmation.
The screen returns to LOCAL.
You can change the temperature set here also in [HEATER] of the [SETUP] menu. ( P.3-4)
The Heater temperature is controllable at the RIP side if the RIP in use has a function controllable.
(For the setting procedures, refer to the instruction manual of the RIP in use.)
Use this machine under 20 to 30°C. The temperature may not reach the set value due to the
environmental temperature condition.
PRE PRT POST
35° C40° C50° C
Heater temperature
confirming display
Current heater temperature
OFF OFF OFF
(23° C23° C23° C)
Heater temperature set in
this machine
40° C40° C50° C
(23° C23° C23° C)
The settable temperature
of POST: 20 to 70°C
The settable temperature of
PRE and PRT: 20 to 60°C
PRE PRT POST
35° C40° C50° C

Table of Contents

Other manuals for MIMAKI UJV500-160