EasyManua.ls Logo

MIMAKI UJV500-160 - Page 184

MIMAKI UJV500-160
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-8
6
Press the key.
Sensor adjustment starts.
7
Rotate the adjustment screw of the throttle valve to
adjust the pressure so that it becomes the proper
value.
Proper value of negative pressure: -5.40kPa
Proper value of positive pressure: 15.00kPa
As the negative pressure changes between ±0.1 kPa, adjust so that the intermediate value may become
the target pressure.
Status of lamp and buzzer for each pressure value
8
Press the key.
The error is released and the negative pressure control starts.
Pressure is informed with the buzzer and the ink bottle lamp as well as the screen display.
For the negative pressure, the buzzer stops within the range of ±0.1kPa. For the positive
pressure, the buzzer stops within the range of ±1.0kPa.
Pressure
Ink bottle lamp Buzzer
Positive pressure Negative pressure
High
~ 8.49 ~ -4.75
Sounds
8.50 ~ 9.49 -4.76 ~ -4.85
9.50 ~ 10.49 -4.86 ~ -4.95
10.50 ~ 11.49 -4.96 ~ -5.05
11.50 ~ 12.49 -5.06 ~ -5.15
12.50 ~ 13.49 -5.16 ~ -5.25
13.50 ~ 14.49 -5.26 ~ -5.35 Stops
Proper
value
14.50 ~ 15.49 -5.36 ~ -5.45 Stops
Low
15.50 ~ 16.49 -5.46 ~ -5.55 Stops
16.50 ~ 17.49 -5.56 ~ -5.65
Sounds
17.50 ~ 18.49 -5.66 ~ -5.75
18.50 ~ 19.49 -5.76 ~ -5.85
19.50 ~ 20.49 -5.86 ~ -5.95
20.50 ~ 21.49 -5.96 ~ -6.05
21.50 ~ 22.49 -6.06 ~ -6.15
22.50 ~ 23.49 -6.16 ~ -6.25
23.50 ~ -6.26 ~
When an error occurs even after you adjusted the pressure, contact your local distributor to call for
service.
** ADJUSTING **
PLEASE WA I T
PRESSURE
:-5.40kPa (-5.40)
Current pressure
value
Target pressure
value
Ink bottle lamp
PLEASE WA I T

Table of Contents