5-12
Message Cause Solution
Time to clean the Y motor has come.
• Turn off the power and vacuum debris of
the Y motor from the vacuuming window.
( P.4-28)
• After the replacement, press the
key on the local screen to
clear the warning.
Time to replace the brush of Y motor
has come.
• The brush of Y motor shall be replaced.
Contact a distributor in your district, our
office, or our call center.
The cover of the media take-up
machine was open was detected.
• Check the cover of the media take-up
machine. Even if you close the cover, if
the same error is displayed, contact a
distributor in your district, our office or our
call center.
The control limit sensor of the media
take-up machine was detected.
• Lower the position of the tension bar at
the take-up side. Even if you lower the
position, if the same message is dis-
played, contact a distributor in your dis-
trict, our office or our call center.
An abnormality occurred in the take-up
status of the media take-up machine.
• Check that the media is set on the media
take-up machine correctly.
• Check that the paper core for taking up
media does not run idle.
The cover of the media feeding
machine was open was detected.
• Check the cover of the media feeding
machine. Even if you close the cover, if
the same error is displayed, contact a
distributor in your district, our office or our
call center.
The control limit sensor of the media
feeding machine was detected.
• Lower the position of the tension bar at
the feeding side. Even if you lower the
position, if the same message is dis-
played, contact a distributor in your dis-
trict, our office or our call center.
An abnormality occurred in the feeding
status of the media feeding machine.
• Check that the media is set on the media
feeding machine correctly.
• Check that the paper core of roll media
does not run idle.
Time to replace the mist filter has come.
• For replaceing the filter, refer to the sepa-
rate “Requests for Daily Care and Main-
tenance”.
A platen heater is disconnected.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
Time to replace the post cure lamp has
come.
• For replaceing the lamp, refer to P.4-34
“About time to replace lamp”.
The cover of the post cure lamp unit
was open was detected.
• Check the cover of the post cure lamp
unit. Even if you close the cover, if the
same error is displayed, contact a distrib-
utor in your district, our office or our call
center.