5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.2 Optional Data Monitor Function
177
5
Transient command
: Settable, : Unsettable
Data type Unit Number
of
words
*1
Number of
communic-
ation data
points
Servo amplifier Transient
ID
Storage device
(response data
(+8 to 11))
content
*2
Remark
MR-
J3(W)-B
MR-
J4(W)-B
Servo motor ID
(SSCNET)/Encoder ID
30 0304H +8: Motor ID
+10: Encoder ID
Servo motor ID
(SSCNET/H)
20 0309H
Encoder resolution [pulse] 2 0 0305H
Servo amplifier serial
number
(First 8 characters)
[characters] 4 0 0306H
Servo amplifier serial
number
(Last 8 characters)
[characters] 4 0 0307H
Servo amplifier
identification information
(First 8 characters)
[characters] 4 0 0310H
Servo amplifier
identification information
(Last 8 characters)
[characters] 4 0 0311H
Servo amplifier S/W No,
(First 8 characters)
[characters] 4 0 0312H
Servo amplifier S/W No,
(Last 8 characters)
[characters] 4 0 0313H
Accumulated power-on time [h] 2 0 0319H
Number of inrush current
switching times
[times] 2 0 031AH
Read alarm history number [items] 1 0 0323H
Alarm history/Detail #1, #2 40 0324H +8: Alarm history #1
+9: Alarm detail #1
+10: Alarm history #2
+11: Alarm detail #2
Alarm history/Detail #3, #4 40 0325H +8: Alarm history #3
+9: Alarm detail #3
+10: Alarm history #4
+11: Alarm detail #4
Alarm history/Detail #5, #6 40 0326H +8: Alarm history #5
+9: Alarm detail #5
+10: Alarm history #6
+11: Alarm detail #6
Alarm history/Detail/
Occurrence time
/[h] 4 0 0328H +8: Alarm history
number #(N+1)
+9: Alarm history
number #(N+1)
detail
+10: Alarm history
number #(N+1)
occurrence time
(2 words)
Alarm occurrence time #1,
#2
[h] 4 0
03
29H
+8: Alarm
occurrence time
#1 (2 words)
+10: Alarm
occurrence time
#2 (2 words)
Alarm occurrence time #3,
#4
[h] 4 0 032AH +8: Alarm
occurrence time
#3 (2 words)
+10: Alarm
occurrence time
#4 (2 words)

Table of Contents