5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.6 Connection of SSCNETIII/H Head Module
201
5
■Status device
Set the device for storage of the status of the SSCNET/H head module with a bit device or word device.
• Refer to device list for the range of bit devices and word devices that can be set. (Page 75 Device List)
• The device uses 16 points (1 point if a word device) from the specified device number. The details stored in the status
device are shown below.
■Monitor device
Set the devices for monitoring the status of SSCNET/H head module with a word device.
• Refer to device list for the range of word devices that can be set. (Page 75 Device List)
• The device uses 10 points per word from the specified device number. The details stored in the status device are shown
below.
Off set Signal name Refresh cycle Details
+0 Unusable
+1
+2
+3
+4
+5
+6
+7 During stop error Operation cycle Can be used to judge whether there is an error or not by the signal turning ON when
a stop error is detected in the SSCNET/H head module.
The applicable error code is stored in the error code signal of the monitor device set
in Monitor device. (Page 201 Monitor device) If error is reset by turning ON the
error reset command, or turning ON the SSCNET/H head module power supply
again, the signal turns OFF.
+8 Unusable
+9
+10
+11
+12
+13
+14
+15 During continue error Operation cycle Can be used to judge whether there is an error or not by the signal turning ON when
a continue error is detected in the SSCNET/H head module.
The applicable error code is stored in the error code signal of the monitor device set
in Monitor device. (Page 201 Monitor device) If error is reset by turning ON the
error reset command, or turning ON the SSCNET/H head module power supply
again, the signal turns OFF.
Off set Signal name Refresh cycle Details
+0 Module operating status Operation cycle Stores the operating status of SSCNET/H head module.
0: No communication
1: STOP status
2: RUN status
3: ERROR status
+1 Error code Stores the error code when an error is detected in the SSCNET/H head module.
(Continue error and stop error)
If error is reset by turning ON the error reset command, or the SSCNET/H head
module power supply is turned ON again, this device is also cleared.
+2 Accumulative count for
communication retry
At a communication retry Holds the accumulative count for communication retry with the SSCNET/H head
module.
+3 Maximum continuous times
for communication retry
Counts each time a communication retry with the SSCNET/H head module occurs.
When communication is successful, the count is "0".
+4 Unusable
+5
+6
+7
+8
+9