5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.8 Compatible Devices with SSCNETIII(/H)
271
5
When FR-A800 series is used, each data is delayed for "update delay time + communication cycle" because
of the update cycle of the inverter. The update delay time for each data is shown in the table below.
External input signal
Set as the following to fetch the external input signal (FLS/RLS/DOG) via FR-A800 series.
■Setting in MT Developer2
Set "Amplifier input" for every axis with signal type in the external signal parameter of axis setting parameter.
■Parameter settings on the inverter side
Refer to the instruction manual of FR-A800 series for parameter settings on the inverter side.
Comparisons of specifications with MR-J4(W)-B
Item FR-A800 series
*1
MR-J4(W)-□B
Amplifier type FR-A800-1, FR-A800-2 MR-J4(W)-B(-RJ)
Control of servo amplifier parameters Set directly by inverter. (Not controlled by Motion CPU.) Controlled by Motion CPU.
External input signal External input signals of FR-A800 series, and bit devices
are available.
External input signals of servo amplifier, and bit devices
are available.
Optional data
monitor (Data
type)
Registered
monitor
• Motor load ratio
• Position F/B
• Encoder position within 1 revolution
• Encoder multi-revolution counter
• Load inertia moment ratio
• Model loop gain
• Converter output voltage
• Cumulative current value
• Torque command
• Optional address of registered monitor
• Effective load ratio
• Regenerative load ratio
• Peak load ratio
• Position F/B
• Encoder position within 1 revolution
• Encoder multi-revolution counter
• Load inertia moment ratio
• Model loop gain
• Bus voltage
• Cumulative current value
• Servo motor speed
• Selected droop pulse
• Unit power consumption
• Unit power consumption (2 word)
• Unit total power consumption
• Instantaneous torque
• Load side encoder information 1
• Load side encoder information 2
• Z-phase counter
• Servo motor thermistor temperature
• Torque equivalent to disturbance
• Overload alarm margin
• Excessive error alarm margin
• Settling time
• Overshoot amount
• Servo motor/Load side position deviation
• Servo motor/Load side speed deviation
• Servo command value
• Torque command
• Internal temperature of encoder
• Optional address of registered monitor
Data type Update delay time of FR-A800 series
10ms
222µs
222µs
222µs
10ms
10ms
5ms
Motor load ratio
Encoder position within 1 revolution
Encoder multi-revolution counter
Load inertia moment ratio
Model loop gain
Converter output voltage
Position F/B