1 MULTIPLE CPU SYSTEM
1.1 Multiple CPU System
29
1
*1 Items that can be set will differ depending on the module used.
*2 Setting range will differ depending on the module used.
Application
setting
Scaling function Scaling enable/disable setting Enable/Disable Disable
Scaling range upper limit value -3276.8 to -0.1, 0.1 to 3276.7
Scaling range lower limit value -3276.8 to -0.1, 0.1 to 3276.7
Scaling width upper limit value -32768 to -1, 1 to 32767
Scaling width lower limit value -32768 to -1, 1 to 32767
Warning output
function
(Process alarm)
Warning output setting (Process
alarm)
Enable/Disable Disable
Process alarm upper upper limit
value
-270.0 to 1820
Process alarm upper lower limit
value
-270.0 to 1820
Process alarm lower upper limit
value
-270.0 to 1820
Process alarm lower lower limit
value
-270.0 to 1820
Warning output
function (Rate
alarm)
Warning output setting (Rate
alarm)
Enable/Disable Disable
Rate alarm detection cycle
setting
1 to 32000 times
Rate alarm upper limit value 0.1 to 3276.7
Rate alarm lower limit value -3276.8 to -0.1
Disconnection
detection
function
Disconnection detection
function enable/disable setting
Enable/Disable Enable
Conversion setting for
disconnection detection
Up scale/Down scale/Given value/Value immediately
before disconnection
Down scale
Conversion setting value for
disconnection detection
-3276.8 to 3276.7
Disconnection detection
automatic clear enable/disable
setting
Enable/Disable Disable
Logging function Logging enable/disable setting Enable/Disable Disable
Logging data setting Measured temperature value/Scaling value
Logging cycle setting value ms: 10 to 32767
s: 1 to 3600
Logging cycle unit setting ms/s
Level trigger condition setting Disable/Level trigger (Condition: Rise)/Level trigger
(Condition: Fall)/Level trigger (Condition: Rise and Fall)
Logging points after trigger 1 to 1000
Trigger data 0 to 9999
Trigger setting value -32768 to 32767
Logging loading enable/disable
setting
Enable/Disable
Logging read points setting
value
1 to 1000
Online module
change
Auto restore of Offset/gain
setting with the module change
Enable/Disable Enable
Interrupt
sett
i
ng
Condition target setting Disable/Error flag/Warning output flag (Process alarm)/
Warning output flag (Rate alarm)/Disconnection detection
flag/Conversion completed flag/Logging hold flag/Logging
read
Disable
Condition target channel setting All CH specification/CH1/CH2/CH3/CH4/CH5/CH6/CH7/
CH8
All CH specification
Interrupt factor transaction setting Interrupt reissue requests/No Interrupt reissue requests Interrupt reissue requests
Interrupt pointer I0 to I15
Item
*1
Setting range
*2
Default value