6 COMMUNICATION FUNCTIONS
6.5 Vision System Connection Function
321
6
Setting batch send (TCP/IP protocol) of multiple data
By using the format output string setting of TCP/IP protocol, image data after the job is finished can be sent in a batch to the
Motion CPU. Set with the following procedure using In-Sight
Explorer.
Operating procedure
1. Click the [Online] icon on the tool bar, and shift to the offline mode.
2. Click the [Communication] button under Application Steps to display the Communications screen.
3. Click the [Add Device] button to display the screen of Device Setup.
4. Select "Other" for "Device".
5. Select "TCP/IP" for "Protocol", and click the [OK] button.
1.
2.
3.
4.
5.
<Screen: In-Sight
®
Explorer>