6 COMMUNICATION FUNCTIONS
6.5 Vision System Connection Function
6. The “TCP/IP” device will be added. Click the [Format String] button to display the FormatString dialog.
7. Set "Use Delimiter", and set the selectable character with "Standard".
8. Click the [Add] button to display the Select Output Data dialog.
9. Select the data to be sent to the Motion CPU as the result of the job execution, and then click the [OK] button.
10. Set "Data Type" for the added data. Select "Integer", "Unsigned Integer" or "Floating Point". The data type stored in the
Motion CPU device is always a 64-bit floating point type regardless of the data type set here.
11. Click [OK] button to close the FormatString dialog.
6.
7.
9.
<Screen: In-Sight
®
Explorer>
8.
10.
<Screen: In-Sight
®
Explorer>
11.