APPENDICES
Appendix 1 Error Codes
419
A
30F9H Operation cycle mixed
setting error
The system of SSCNET has already existed in
network setting when setting low-speed operation cycle
setting magnificent.
The operation cycle is 0.222[ms] when setting low-
speed operation cycle setting magnificent.
The operation cycle is 0.444[ms] when setting low-
speed operation cycle setting magnificent as 8 times.
"Low-speed operation cycle setting magnificent
operation cycle" exceeds 14.222[ms].
The machine control function is valid when setting low-
speed operation cycle setting magnificent.
The servo amplifier axis or command generation axis
for executing control in low-speed operation cycle does
not exist.
G-code control setting is valid when low-speed
operation cycle magnificent setting is valid.
Change the network setting to SSCNET/H.
Set the operation cycle to 0.444[ms] or more.
Set the operation cycle to 0.888[ms] or more when low-
speed operation cycle setting magnificent is 8 times.
Check and correct the setting to make "low-speed
operation cycle setting magnificent operation cycle"
less than 14.222[ms].
Disable the machine control function.
Check and correct the servo network setting or the
control operation cycle setting of command generation
axis setting.
Change G-code control setting to "Not Used".
30FAH Machine configuration
error
Machine parameter or the axis setting parameter of the
machine configuration axis is incorrect.
Confirm the detail code and check the adequate
parameter setting. (For the detail code, refer to
MELSEC iQ-R Motion Controller Programming
Manual (Machine Control).)
30FBH Machine control device
assignment error
The using device of machine is outside the assignment
range of device.
Set the using device of machine within the range of device
assignment.
30FDH G-code control
configuration error
The parameter of G-code control configuration axis is
incorrect.
An error has been detected when reading G-code
program.
Confirm the detail code and check the adequate
parameter setting.
Confirm the detail code, eliminate the error and execute
program writing again. (For the detail code, refer to
MELSEC iQ-R Motion Controller Programming
Manual (G-Code Control).)
30FEH G-code control operation
cycle setting error
The operation cycle is less than 0.888[ms] when setting
G-code control.
Check and correct the operation cycle over 0.888[ms]
when using G-code control.
30FFH G-code control add-on
library incorrect
Add-on library is not installed when setting G-code control. Install the add-on library of G-code control.
Select "Not Used" in G-code control setting of the basic
setting when not use G-code control.
Error
code
Error name Error details and cause Corrective action

Table of Contents