APPENDICES
Appendix 4 Special Registers
449
A
SD715 Low speed Motion
operation cycle
Low speed Motion operation
cycle
The time taken for low speed Motion operation cycle is stored in [s]
units.
0 to 65535[s]
S (Low speed
operation cycle)
SD716 Low speed Motion
maximum operation
cycle
Low speed Motion maximum
operation cycle
• The maximum time taken for low speed Motion operation cycle is
stored in [s] units.
0 to 65535[s]
• When "0" is written, the maximum value is reset.
SD717 Operation cycle
counter
Operation cycle counter • Incremented by 1 each time the Motion operation cycle is executed,
and when 65535 is exceeded the count returns to 0 and starts again.
0 to 65535
• When low speed Motion operation cycle is enabled, the count returns
to 1 and starts again if the low speed operation cycle magnification
setting is exceeded. (The low speed Motion operation cycle is
executed when this counter is 1.)
1 to low speed operation cycle magnification setting
S (Operation
cycle)
SD718 888s free-running
timer
888s free-running timer Current value (SD718, SD719) is incremented by 1 every 888s.
Read SD718 device in 2 word unit.
S (Every 888s)
SD719
SD720 444s free-running
timer
444s free-running timer Current value (SD720, SD721) is incremented by 1 per 444s.
Read SD720 device in 2 word unit.
S (Every 444s)
SD721
SD722 222s free-running
timer
222s free-running timer Current value (SD722, SD723) is incremented by 1 per 222s.
Read SD722 device in 2 word unit.
S (Every 222s)
SD723
No. Name Data stored Details Set by
(setting
timing)
Item Specification
Data size
Latch
Usable tasks
Access
Timer specifications
888
μ
s timer
2 word (-2147483648 to 2147483647)
Cleared to zero at power supply on or reset,
counting is continued thereafter.
Normal, event, NMI
Read enabled only
Item Specification
Data size
Latch
Usable tasks
Access
Timer specifications 444
μ
s
timer
2 word (-2147483648 to 2147483647)
Cleared to zero at power supply on or reset,
counting is continued thereafter.
Normal, event, NMI
Read enabled only
Item Specification
Data size
Latch
Usable tasks
Access
Timer specifications 222
μ
s timer
2 word (-2147483648 to 2147483647)
Cleared to zero at power supply on or reset,
counting is continued thereafter.
Normal, event, NMI
Read enabled only