6
- 79
6.13 Execution Time Measurement
6.13.3 Scan time measurement
6
FUNCTIONS
(6) Precautions
(a) When measurement range is set
Set the "Measurement limit" so that the value of "Start step" is larger than that of
"End step".
(b) Measurement of scan time across program files
The scan time to skip to another program file cannot be measured.
(c) When measurement time is less than 0.100ms
If the measurement time is less than 0.100 ms, 0.000 ms is displayed.
(d) When measurement range is specified between FOR and NEXT instructions
If a measurement range is specified between the FOR instruction and the NEXT
instruction, scan time will show the execution time of making a measurement in
the measurement range between specified steps.