8-43
Updating Controller Firmware
iControl AC
8
15. Click Start upgrade. The upgrade progress will be indicated in the text window. When
the upgrade is completed you will be instructed to close iView and press the iBox Com-
puter Reset button.
16. Use iView to connect to the iBox when it finishes the re-boot.
17. Select About iView from the Help menu and verify the version numbers for the IMP
Application and IMP Bootrom.
18. If you want to restore the original parameter settings which were saved in step #3, first
acquire write privilege and then select Load from the File > Configuration menu. Please
refer to “Loading Parameters from a Configuration File” on page 8-22.
19. Select and Open or double click the desired file from the Open Configuration File dialog.
20. Select All screens or the Selected screens for which you wish to restore the original
parameter settings, and click OK.
Upgrade Options
When upgrading firmware from a pre-December 2005 release to a later release, in the event
that the Upgrade Wizard fails to properly load the parameters file, iView may not be able to con-
nect to the upgraded controller. The Upgrade Options Dialog (File > Upgrade Options) can be
used to enable iView to connect to the controller or iCue and complete the upgrade.

Table of Contents