EasyManua.ls Logo

Motion Control Engineering Nidec iControl - Page 393

Default Icon
453 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-28 Manual # 42-02-2223
Reference
LE35
Encoder 2
Output PPR
Source
Channel 1
Channel 2
Actual Value
Reserved
Actual
Value
256
512
1024
2048
Division
Direct
2
4
8
16
32
64
128
0
1
2
3
0
4
8
12
0
16
32
48
64
80
96
112
--
Channel 1
Direct
LE36
Encoder 2
PT1 Time
- - 0-255 ms 0
LN Machine Data Parameters
LN01
Traction S h e ave
Diameter
-
-
3.94-62.99
in 24.00
LN02
Gear
Reduction Ratio
- - 1.00250.00 x:1 30.00
LN03 Roping Ratio - - 1-4 x:1 1
LN04 Load - - 0-30000 lb 0
LN05
Estimated Gear
Reduction
- - 0.00 x:1 Calculated
LS Speed Profile Parameters
LS01 Leveling Speed - - 0-25 ft/min 4
LS02 High Speed (set to Contract Speed) - 0-1600 ft/min 0
LS03
Inspection
Speed
(Set to 150 or Contract
Speed which ever is less)
- 0-150 ft/min 150
LS04
Correction
Speed
--0-50ft/min0
LS05
Intermediate
Speed 1
- - 0-1600 ft/min 0
LS06
Intermediate
Speed 2
- - 0-1600 ft/min 0
LS07
Intermediate
Speed 3
- - 0-1600 ft/min 0
LS08
Earthquake
Speed
- - 0-150 ft/min 0
LS09
Emergency
Power Speed
- - 0-1600 ft/min 0
LS10
Battery Opera-
tion Speed
(Set to 50 or Contract Speed
which ever is less)
-0-50ft/min50
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default
Field
Setting

Table of Contents