9-29
TORQMAX F5 Drive v3.xx Parameters Table
iControl AC
9
LS15 High Speed
Profile
Profile Setting
Custom
Medium
Soft
Hard
0
1
2
3
--
(0); Custom
+ External
Profile
Profile
Source
External Profile
Internal Profile
0
4
LS16
One Floor
Profile
Custom
Medium
Soft
Hard
0
1
2
3
--Custom
LS17
Emergency
Profile
Same as LS16
ā€œ ā€œ
--Custom
LS20
Acceleration
High Speed
-
- 0.30-12.00
ft/
sec
2
2.30
- 0.091-3.662
m/s
2
0.701
LS21
Start Jerk High
Speed
- - 0.30-32.00
ft/
sec
3
2.30
LS22
Accel. Jerk
High Speed
- - 0.30-32.00
ft/
sec
3
2.30
LS23
Deceleration
High Speed
- - 0.30-12.00
ft/
sec
2
2.30
LS24
Decel. Jerk
High Speed
- - 0.30-32.00
ft/
sec
3
2.30
LS25
Stop Jerk High
Speed
- - 0.30-32.00
ft/
sec
3
2.30
LS27 High Speed
Correction
- - 0.0-6.00 in
0.0
LS30
Acceleration
One Floor
- - 0.30-12.00
ft/
sec
2
3.00
LS31
Start Jerk One
Floor
- - 0.30-32.00
ft/
sec
3
3.00
LS32
Accel. Jerk One
Floor
- - 0.30-32.00
ft/
sec
3
3.00
LS33
Deceleration
One Floor
- - 0.30-12.00
ft/
sec
2
3.00
LS34
Decel. Jerk One
Floor
- - 0.30-32.00
ft/
sec
3
3.00
LS35
Stop Jerk One
Floor
- - 0.30-32.00
ft/
sec
3
3.00
LS37
Int. Speed 1
Correction
- - 0.0-6.0 in 0.0
LS38
Int. Speed 2
Correction
- - 0.0-6.0 in 0.0
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default