9-30 Manual # 42-02-2223
Reference
LS40
Acceleration
Emergency
- - 0.30-12.00
ft/
sec
3
1.50
LS41
Start Jerk
Emergency
-
- 0.30-32.00
ft/
sec
3
1.50
- 0.091-9.759
m/s
3
0.460
LS42
Accel. Jerk
Emergency
- - 0.30-32.00
ft/
sec
3
1.50
LS43
Deceleration
Emergency
- - 0.30-12.00
ft/
sec
2
1.50
LS44
Decel. Jerk
Emergency
- - 0.30-32.00
ft/
sec
3
1.50
LS45
Stop Jerk
Emergency
- - 0.30-32.00
ft/
sec
3
1.50
LS47
Int. Speed 3
Correction
- - 0.0-6.0 in 0.0
LS48
ESD/ETS
Deceleration
- - 0.30-12.00
ft/
sec
2
4.00
LS49 ESD/ETS Jerk - - 0.30-32.00
ft/
sec
3
4.00
LS50
Acceleration
Inspection
- - 0.30-12.00
ft/
sec
2
2.00
LS51
Start Jerk
Inspection
- - 0.30-32.00
ft/
sec
3
2.00
LS52
Accel. Jerk
Inspection
- - 0.30-32.00
ft/
sec
3
2.00
LS53
Deceleration
Inspection
- - 0.30-12.00
ft/
sec
2
2.00
LS54
Decel. Jerk
Inspection
- - 0.30-32.00
ft/
sec
3
2.00
LS55
Stop Jerk
Inspection
- - 0.30-32.00
ft/
sec
3
2.00
LL Tune Parameters
LL01 Motor Tuning
Off
Start
0
1
--Off
LL02 Tuning Current PM only 10-100 % 100
LL05 SPI
PM only
Off
Start
0
1
Off
LL06 Encoder
Pole Position
Learn
PM only
Off
Start
0
1
Off
LL07 Encoder Syn-
chronization
Off
Start
0
1
Off
LL10 Inertia Learn
Off
Start
0
1
Off
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default
Field
Setting