9-64 Manual # 42-02-2223
Reference
C3 Logic Outputs submenu
LOGIC OUTPUT 1
TB1(25)
Logic Output 1 None Alarm,
alarm+flt,
auto brake,
brake hold,
brake pick,
brk hold flt
brk pick flt,
car going dwn,
car going up
, charge fault,
close contact,
contactor flt,
curr reg flt,
drv overload,
encoder flt,
fault,
flux confirm,
ground fault,
in low gain,
motor trq lim,
mtr overload,
no faults,
no function,
not alarm,
over curr flt,
overspeed flt,
overtemp flt,
overvolt flt,
ovrtemp alarm,
phase fault,
ramp down
ena,
ready 2 start,
ready to run,
regen trq lim,
run com-
manded,
run confirm,
speed dev,
speed dev low,
speed ref rls,
speed reg rls,
undervolt flt,
up to speed,
uv alarm,
zero speed
CLOSE
CON-
TACT
CLOSE
CON-
TACT
LOGIC OUTPUT 2
TB1(26)
Logic Output 2 None RUN
COM-
MANDE
D
RUN
COM-
MANDE
D
LOGIC OUTPUT 3
TB1(27)
Logic Output 3 None MTR
OVER-
LOAD
MTR
OVER-
LOAD
LOGIC OUTPUT 4
TB1(28)
Logic Output 4 None ENCODE
R FLT
ENCOD
ER FLT
LOGIC OUTPUT 5
TB1(29)
Logic Output 5 None FAULT FAULT
LOGIC OUTPUT 6
TB1(30)
Logic Output 6 None SPEED
REG
RLS
SPEED
REG
RLS
LOGIC OUTPUT 7
TB1(31)
Logic Output 7 None SPEED
REG
RLS
SPEED
REG
RLS
SSR1 TB1(21/22) Solid State Relay #1 None NO
FUNC-
TION
NO
FUNC-
TION
SSR2 TB1(23/24) Solid State Relay #2 None NO
FUNC-
TION
NO
FUNC-
TION
RELAY COIL 1 TB2
(1/3/5)
Relay Coil #1 None NO
FUNC-
TION
NO
FAULT
RELAY COIL 2 TB2
(8/10/12)
Relay Coil #2 None NO
FUNC-
TION
SPEED
REG
RLS
Table 10. Quattro PM Elevator Drive, iControl