9-65
Magnetek Quattro AC Quick Reference
iControl AC
9
C4 Analog Outputs submenu
ANA OUT 1 TB1-12 Analog output #1 None − analog addr2
− analog addr3
− arm current
− arm voltage
− aux torq cmd
− bus voltage
− est motor spd
− field current
− arm error
− ls pwr input
− pretorque ref
− motor mode
− spd rg tq cmd
− speed com-
mand
− speed error
− speed feedbk
− speed ref
− tach rate cmd
− tach speed
− torque ref
SPEED
REF
SPEED
REF
ANA OUT 2 TB1-13 Analog Output #2 None SPEED
FEEDBK
SPEED
FEEDB
K
Table 11. Utility U0 Menu
U0 Param Desc Default Choices
U1 Password Data protection password.
Enter Password Allows password entry 012345
New Password
Password Lockout Enable password lockout Disabled enabled
disabled
U2 Hidden Items
Hidden Items Allows selected parameters to be blocked from drive
display.
Enabled enabled
disabled
U3 Units
Unit Selection Metric or English unit selection English metric
english
U4 Overspeed Test
Overspeed Test? Allows an overspeed test to be run from drive opera-
tor.
No Yes
No
U5 Restore Defaults
Restore drive defaults? Resets all parameters in A1, A2, A3, A4, C1, C2, C3,
and C4 submenus. Also resets A6 parameters Flux
Confirm Lev, Tach Volt Sense, Tach speed sense, Ovld
Start Level, and Ovld time out.
No Yes
No
Restore motor defaults? Restores motor params to default value. No Yes
No
Restore Utility Defaults? Resets A5 submenu parameters to default values.
Also resets Gain Selection in the A4 submenu.
No Yes
No
U6 MS Drive Info Motor Side Drive Information
Table 10. Quattro PM Elevator Drive, iControl