9-71
TORQMAX F5 Drive v1.xx Parameters Quick Refer-
iControl AC
9
TORQMAX F5 Drive v1.xx Parameters Quick Reference
This section includes quick reference information for the TORQMAX F5 drive parameters.
Please refer to the F5 drive manual provided with the iControl for a detailed explanation.
For Permanent magnet (PM Synchronous) motors, consult the following sections of the TORQMAX
F5 Drive manual before roping the machine, 5.5 PM Synchronous Motors, 5.8 Encoder Feedback
and 5.11 Running the Motor.
Table 9.1 TORQMAX F5 Drive Parameters Quick Reference for iControl AC
WARNING: Do not change drive parameters while the elevator is running. Incorrect drive parame-
ters can cause erratic elevator operation. Parameters with an asterisk (*) must be set correctly
for your specific motor/machine. Refer to the drive adjustment manual for detailed information.
Digital
Operator
Display
Parameter Description Unit
Setting
Range
Default
Setting
Factory
Setting
LF.02
Signal operating mode:
AbSpd = Absolute Analog Speed
d SPd = Digital speed control
A tor= Analog torque control
A Spd= Analog speed control
SErSP = Serial Com. Speed Control
bnSPd = Binary Speed Selection
S POS = Serial Position Feedback
-
AbSpd
d SPd
A tor
A Spd
SErSP
bnSPd
bnSPd A Spd
LF.03 Drive configuration:
run = run mode
conF = Configuration (5 minute time limit)
Stop = Drive Stopped, Motor cannot run.
S Lrn = activate auto tune
I Lrn = Inertia Learn. Learns system inertia.
P Lrn = Pole Learn. PM motor pole positions.
SPI = Learns absolute encoder position for PM
motor without sheave movement. ****
OStST = Allows car to over speed for one run
without changing drive parameters
(see also LF.49).****
-
run
conF
Stop
S Lrn
I Lrn
P Lrn
SPI
OStST
conF run
LF.04
Motor selection: Displays mode selected using
US.4 and US.10
-
Read only.
See US.10
- ***
LF.05 Drive fault auto reset 1 0-10 5 5
LF.08 Electronic motor overload protection - on/off off on
LF.09
Electronic overload current:
PM- Not visible, auto set same as LF.12.
A
1.0 - 110%
Rtd
8.0
*________
LF.10
Rated motor power
PM- Read only, auto calc.
HP
0.00 -
125.00
5.0
IM*______
LF.11 Rated motor speed rpm 10.0-6000 1165 or 150 *________
LF.12 Rated motor current A
1.0 - 110%
Drive rated
8.0
*________
LF.13 Rated motor frequency Hz 4.0 - 100.0 60.0 *________
LF.14
Rated motor voltage
IM - Name plate rated voltage (120 - 500V)
PM - No-load, phase-to-phase back EMF rms
voltage LF.11 (1 - 32000V/krpm)
V - 230/460
*________