Motorola Solutions AP-6511 Access Point System Reference Guide
12-34
6. Select the Run Calibration option to initiate a calibration. New channel and power values are applied
to radios, they are not written to the running-configuration. These values are dynamic and may keep
changing during the course of the run-time monitoring and calibration the Smart RF module keeps
performing to continually maintain good coverage. Unlike an Interactive Calibration, the Smart RF screen
is not populated with the changes needed on Access Point radios to remedy a detected coverage hole.
Expand the screen to display the Event Monitor to track the progress of the calibration.
The calibration process can be stopped by selecting the Stop Calibration button.
Discard Discards the results of the Interactive Calibration without applying them
to their respective devices.
Commit Commits the Smart RF module Interactive Calibration results to their
respective Access Point radios.