11. Refer to the TCP Protocol Checks field to set the following parameters:
12. Select OK to update the Firewall Policy Advanced Settings. Select Reset to revert to the last saved
configuration.
8.1.2 Configuring IP Firewall Rules

Wireless Firewall
Devices use IP based Firewalls like Access Control Lists (ACLs) to filter/mark packets based on the IP from
which they arrive, as opposed to filtering packets on Layer 2 ports.
Stateless TCP Flow Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 90 seconds.
Stateless FIN/RESET
Flow
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 10 seconds.
ICMP Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 30 seconds.
UDP Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 90 seconds.
Any Other Flow Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 5 seconds.
Check TCP states
where a SYN packet
tears down the flow
Select the radio button to allow a SYN packet to delete an old flow in
TCP_FIN_FIN_STATE and TCP_CLOSED_STATE and create a new flow. The
default setting is enabled.
Check unnecessary
resends of TCP
packets
Select the radio button to enable the checking of unnecessary resends of
TCP packets. The default setting is enabled.
Check Sequence
Number in ICMP
Unreachable error
packets
Select the radio button to enable sequence number checks in ICMP
unreachable error packets when an established TCP flow is aborted.The
default setting is enabled.
Check
Acknowledgment
Number in RST
packets
Select the radio button to enable the checking of the acknowledgment
number in RST packets which aborts a TCP flow in the SYN state. The
default setting is enabled.
Check Sequence
Number in RST
packets
Select the radio button to check the sequence number in RST packets
which abort an established TCP flow. The default setting is enabled.

Table of Contents

Other manuals for Motorola AP-6511

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola AP-6511 and is the answer not in the manual?

Motorola AP-6511 Specifications

General IconGeneral
BrandMotorola
ModelAP-6511
CategoryWireless Access Point
LanguageEnglish

Related product manuals