EasyManuals Logo

NAiS FP Series Hardware Manual

NAiS FP Series
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
FP0 HardwareI/O Allocation
7-4
Matsushita Electric Works (Europe) AG
7.3 Expansion I/O Unit
Up to three expansion I/O units can be added.
I/O numbers do not need to be set as I/O allocation is performed automatically by the
FP0 control unit when an expansion I/O unit is added.
The I/O allocation of expansion I/O unit is determined by the installation location.
I/O number
Type
First
expansion
Second
expansion
Third
expansion
E8RS Input: 4 points
ÁÁÁÁÁ
ÁÁÁÁÁ
X20 to X23
ÁÁÁÁÁ
ÁÁÁÁÁ
X40 to X43
ÁÁÁÁÁ
ÁÁÁÁÁ
X60 to X63
Output: 4 points
ÁÁÁÁÁ
ÁÁÁÁÁ
Y20 to Y23
ÁÁÁÁÁ
ÁÁÁÁÁ
Y40 to Y43
ÁÁÁÁÁ
ÁÁÁÁÁ
Y60 to Y63
E8X Input: 8 points
ÁÁÁÁÁ
ÁÁÁÁÁ
X20 to X27
ÁÁÁÁÁ
ÁÁÁÁÁ
X40 to X47
ÁÁÁÁÁ
ÁÁÁÁÁ
X60 to X67
E8YT/E8YP Output: 8 points
ÁÁÁÁÁ
ÁÁÁÁÁ
Y20 to Y27
ÁÁÁÁÁ
ÁÁÁÁÁ
Y40 to Y47
ÁÁÁÁÁ
ÁÁÁÁÁ
Y60 to Y67
E16RS/E16T/E16P Input: 8 points
ÁÁÁÁÁ
ÁÁÁÁÁ
X20 to X27
ÁÁÁÁÁ
ÁÁÁÁÁ
X40 to X47
ÁÁÁÁÁ
ÁÁÁÁÁ
X60 to X67
Output: 8 points
ÁÁÁÁÁ
Y20 to Y27
ÁÁÁÁÁ
Y40 to Y47
ÁÁÁÁÁ
Y60 to Y67
E16X Input: 16 points
ÁÁÁÁÁ
ÁÁÁÁÁ
X20 to X2F
ÁÁÁÁÁ
ÁÁÁÁÁ
X40 to X4F
ÁÁÁÁÁ
ÁÁÁÁÁ
X60 to X6F
E16YT/E16YP Output: 16 points
ÁÁÁÁÁ
ÁÁÁÁÁ
Y20 to Y2F
ÁÁÁÁÁ
ÁÁÁÁÁ
Y40 to Y4F
ÁÁÁÁÁ
ÁÁÁÁÁ
Y60 to Y6F
E32T/E32P Input: 16 points
ÁÁÁÁÁ
ÁÁÁÁÁ
X20 to X2F
ÁÁÁÁÁ
ÁÁÁÁÁ
X40 to X4F
ÁÁÁÁÁ
ÁÁÁÁÁ
X60 to X6F
Output: 16 points
ÁÁÁÁÁ
ÁÁÁÁÁ
Y20 to Y2F
ÁÁÁÁÁ
ÁÁÁÁÁ
Y40 to Y4F
ÁÁÁÁÁ
ÁÁÁÁÁ
Y60 to Y6F
Third expansion
Second expansion
First expansion
Control unit

Table of Contents

Other manuals for NAiS FP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAiS FP Series and is the answer not in the manual?

NAiS FP Series Specifications

General IconGeneral
BrandNAiS
ModelFP Series
CategoryController
LanguageEnglish

Related product manuals