Features
Voice Mail, Local
Networking 93
Voice Mail, Local
Voice Mail, Local
With a networked system, with each system having their own voice mail, in order for users to prop-
erly connect to the correct voice mail when leaving a message, the programming must be set as
described below.
PRI Networking
Each node on a networked Aspire system is deÞned in Program 10-03-11 : PCB Setup - Network-
ing System Number for the desired PRI slot. In the local system (System 1), Program 11-01-01 :
System Numbering has a digit deÞned for networking (example: 7x=8 (network)).
The ID entry in Program 10-03-11 must match the ID set in Program 11-01-01. Otherwise, callers
could not press "8" to leave a message at a networked user’s voice mail. For example:
In System 1 in Program 10-03-11 = 1, Program 11-01-01 7X=8, ID = 2.
When System 1’s extension 301 calls System 2’s extension 401, then presses digit "8",
the user would hear a reorder tone.
In System 1 in Program 10-03-11 = 1, Program 11-01-01 7X=8, ID = 1.
When System 1’s extension 301 calls System 2’s extension 401, then presses digit "8",
the user will hear the voice mail message for extension 401.
Note that in order to assign a system ID, the "type" must temporarily be set to "8" (networking).
Once the system ID has been assigned, you can change the type to the required entry (2).
PRI Networking With Two Local Voice Mails, Masters Must Have Different Numbering
When programming a PRI network with each system having their own local voice mail, the master
numbers for the voice mails must be deÞned in different series in Program 11-01. The second digit
of the extension number can not be the same. For example, 700 and 701 will not work, however 700
and 710 can be used.
Related Programs
Step Program Number Title
1. 11-01-01 System Numbering Plan
Set Program 11-01-01 to "8" (networking) for the
local and remote voice mail master numbers and deÞne
the ID number.
2. 10-03-11 PCB Setup - Networking System Number
Set the local system ID in to the same entry deÞned
in Program 11-01-01.
3. 11-01-01 System Numbering Plan
Change Program 11-01-01 for the local voice mail
master number back to "2" (extension number).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Aspire Series and is the answer not in the manual?

NEC Aspire Series Specifications

General IconGeneral
SeriesAspire
ProtocolsSIP, H.323
LinesIP
ExtensionsDigital, IP
VoicemailIntegrated Voicemail System
NetworkingIP Networking
Power Supply100-240V AC, 50/60Hz
DimensionsVaries depending on the system module
WeightVaries depending on the system module