Programming
22-10 : DID Translation Table Setup
178 Networking
22-10 : DID Translation Table Setup
Description
Use Program 22-10 : DID Translation Table Setup to specify the size of the DID Translation
Tables. There are 2000 Translation Table entries that you can allocate among 20 Translation Tables.
Conditions
None
Input Data
Default
Conditions
None
Level:
Aspire S Aspire M/L/XL
IN Available. Available.
Applicable to IP and ISDN Networking. Applicable to IP and ISDN Networking.
Conversion Table Area Number 01-20
Item No. Item Input data
01 1st Area Setup (Start Address) 0-2000
(0 = No setting)
1st Area Setup (End Address)
2nd Area Setup (Start Address)
2nd Area Setup (End Address)
Conversion Table Area 1st 2nd
Start Table End Table Start Table End Table
1 1 100 0 0
2 101 200 0 0
3 201 300 0 0
4 301 400 0 0
: ::::
20 0000