EasyManuals Logo

NEC Aspire Series User Manual

NEC Aspire Series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Features
ARS/F-Route
40 Networking
ARS/F-Route
ARS/F-Route
Digits dialed by a user can be routed based on ARS programming or F-Route tables. In general,
ARS provides the simpler solution, as long as outgoing trunk order/trunk priority is not required.
(For instance, POTS lines used Þrst, if these are busy, then networked trunks are used.)
ARS
When using ARS, keep the following items in mind:
ARS must for activated on all networked sites.
You need to make sure the 911 calls route at the site from which they are dialed.
If you wish to have outgoing calls use one group of trunks Þrst and, when those trunks
become busy, go out over the network trunks, F-Routing must be used. The order must be the
your own site’s trunks and then the other site’s trunks. It will not work in the reverse.
Example:
Site A: Use group 1 for all calls.
Site B: Use "Group 1" trunks for local calls and network trunks. Use "Group 101" for long
distance calls in the 1 + 203 area.
The following represents a standard ARS conÞguration that should be done anytime you setup ARS.
Program Site A (far end)
Site B (near end)
(All 1203-xxx-xxxx calls to go
out site A's trunks)
Program 26-01-01
ARS Service
1 (ARS enabled) 1 (ARS enabled)
Program 26-02-01
Dial Analysis Table for
ARS Access
002=1203@@@@@@@
Program 26-02-03
Group Number for Dial
Analysis Table
101 (10"1"= 10-27-01
network site 1)
Program 26-02-01
Dial Analysis Table for
ARS Access
Entries:
001=911
391=1@@@@@@@@@@
392=2@@@@@@
393=3@@@@@@
394=4@@@@@@
395=5@@@@@@
396=6@@@@@@
397=7@@@@@@
398=8@@@@@@
399=9@@@@@@
400=0
Entries:
001=911
391=1@@@@@@@@@@
392=2@@@@@@
393=3@@@@@@
394=4@@@@@@
395=5@@@@@@
396=6@@@@@@
397=7@@@@@@
398=8@@@@@@
399=9@@@@@@
400=0
Program 26-02-02
Service Type for Dial
Analysis Table
Type 1 = Incoming Ring
Group (for all above entries)
Type 1 = Incoming Ring
Group (for all above entries)
Program 26-02-03
Group Number for Dial
Analysis Table
1 (deÞned in 14-05-01)
(for all above entries)
1 (deÞned in 14-05-01)
(for all above entries except
table 002 when using this
example setup)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Aspire Series and is the answer not in the manual?

NEC Aspire Series Specifications

General IconGeneral
SeriesAspire
ProtocolsSIP, H.323
LinesIP
ExtensionsDigital, IP
VoicemailIntegrated Voicemail System
NetworkingIP Networking
Power Supply100-240V AC, 50/60Hz
DimensionsVaries depending on the system module
WeightVaries depending on the system module

Related product manuals