Programming
44-02 : Dial Analysis Table for ARS/F-Route Access
Networking 197
44-02 : Dial Analysis Table for ARS/F-Route Access
Description
Use Program 44-02 : Dial Analysis Table for ARS/F-Route Access to set the Pre-Transaction
Table for selecting ARS/F-Route.
Input Data
Level:
Aspire S Aspire M/L/XL
IN Available. Available.
Applicable to IP and ISDN Networking. Applicable to IP and ISDN Networking.
Dial Analysis Table Number 1-120
Item No. Item Input Data Default
01 Dial
Set the number of digits to be analyzed by the
system for ARS routing.
Up to 8 digits
(Use line key 1 for a “Don’t Care”
digit, @)
No
setting
02 Service Type
Service Type 1 (Extension number)
The number goes to an extension after delet-
ing the front digit(s).
Additional data
Assign the digit(s) to be deleted on top of the
number for extension number usage. There
must be at least one digit deleted.
Service Type 2 (ARS/F-Route)
The number is controlled by ARS/F-Route
table.
Additional data
If the ARS/F-Route Time Schedule is not
used, assign the ARS/F-Route table number
for Program 44-05.
If the ARS/F-Route Time Schedule is used,
assign the ARS/F-Route selection number for
Program 44-04.
Service Type 3 (Dial Extension Analyze
Table)
The total length of the number exceeds more
than 8 digits.
Additional data
Assign the Dial Extension Analysis Table
number to be used in Program 44-03.
0=No setting
1=Extension Call
2=ARS/F-Route Table
3=Dial Extension Analyze Table
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Aspire Series and is the answer not in the manual?

NEC Aspire Series Specifications

General IconGeneral
SeriesAspire
ProtocolsSIP, H.323
LinesIP
ExtensionsDigital, IP
VoicemailIntegrated Voicemail System
NetworkingIP Networking
Power Supply100-240V AC, 50/60Hz
DimensionsVaries depending on the system module
WeightVaries depending on the system module