Programming
10-03 : PCB Setup
Networking ◆ 117
For T1 Unit
For VMSU Unit
For VOIPU Unit
Physical Port Number 01-32
Item
No.
Item Input Data Default
01 Logical Port Number 0-200 0
02 Frame Type Setup 0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
0
03 Zero Code Suppression Setup
ZCS_B8ZS
0 = B8ZS
1 = AMI/ZCS
0
04 DTI<->CSU Distance Setup 0= 0 feet – 133 feet
1= 133 feet – 266 feet
2= 266 feet – 399 feet
3= 399 feet – 533 feet
4= 533 feet – 655 feet
0
05 T1 Clock Source Master/Slave 0 = Internal
1 = External
1
Prior to 2.65 = 0
Item
No.
Item Input Data Default
01 Logical Port Number Through Software 3.07: 0-256
From Software 4.0E+: 0-384
0
Physical Port Number 01-32
Item
No.
Item Input Data Default
01 Trunk Logical Port Number 0-200 0
02 H.323 or SIP Trunk
Determine the IP trunk type setup. If SIP
trunking is used, this reduces the number
of ports on the VOIPU card which can be
used for Aspire IP phones or IP network-
ing. With SIP trunking, some ports must
be deÞned for SIP.
Contact Your NEC Sales Representative
for information on the SIP feature
availability.
0 = H.323
1 = SIP
0