7. Using Remote Management
Chapter 3 Setup
Item name
Description
Setup value
Default setting(*1)
Management
Software
ESMPRO
Management
(*8)
Enable or disable
the feature to
monitor or manage
the server from
NEC ESMPRO
Manager.
If Enabled, NEC
ESMPRO
Manager can
remotely monitor
or manage the
server.
Enable/Disable
Enable
Authentication
key (*9)
When ESMPRO
Management is
enabled, specify
authentication key
used to access
BMC,
Authentication key when
managed by NEC ESMPRO
Manager (*10)
guest
Redirection
(LAN)(*9)
Enable or disable
the feature to
display Serial Over
Lan (SOL) screen
from NEC
ESMPRO
Manager.
Enable/Disable Enable
(*1) Factory-set value.
(*2) SEL is cleared when changed from "Overwrite oldest SEL" to other setting, or from other setting to
"Overwrite oldest SEL".
(*3) Use this setting when NEC ESMPRO Agent is used.
(*4) At least one interface must be enabled to configure operation log.
(*5) If "Power Save" in System BIOS is set to Enabled, this item is set to "Power On".
(*6) Not displayed when AC-Link is set to "Stay Off". Specify the delay time from AC power-on to DC
power-on.
(*7) Enable or disable alert from BMC. When "Disable" is selected, SNMP alert is not sent from BMC.
(*8) Select "Enable" to let NEC ESMPRO Manager manage BMC directly.
(*9) Displayed only when "Enable" is selected for ESMPRO Management.
(*10) Up to 16 characters of 1-byte alphanumeric can be accepted.