EasyManua.ls Logo

NEC express5800 A2010b - Page 371

NEC express5800 A2010b
491 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. Using Remote Management
Chapter 3 Setup
Setting range and default value
Item Description When applied
Default
value(*1)
Power
PSU Redundancy
Specify the redundancy of power
supply unit.
2N: Power supply system redundant
mode (2N redundancy)
N+1: Power supply unit redundant
mode (N+1 redundancy)
N: Non-redundant mode (N
configuration)
At next boot
2N
Maintenance
Maintenance Mode
Select whether the maintenance
personnel can work with the system in
this mode, and specify the time allowed
for maintenance. Specify the allowed
time in unit of minute, in the range
between 6 and 1440).
While this mode is on, an icon is
displayed at upper right corner of
screen.
Disable: Allowed time for
maintenance (default): 0 minute
Enable: Allowed time for
maintenance (default): 6 minutes
Immediate
Disable
Maintenance Account Password
Set password for maintenance user.
(*4)
Immediate
Displayed by
[*].
Cooling
BBU on PCI Slot
Specify whether the battery backup unit
is installed on PCI card for external
SAS RAID. Change this parameter to
"Installed" when BBU is mounted. The
setting of power-saving mode of fan
control is also changed according to
this setting.
Not-Installed
Installed
At next boot Not-Installed
Fault Handling
Failing Unit Removal
Specify whether the failing component
is to be disconnected automatically.
Disable
Enable
Enable: Enables automatic removing of
the failing units.
Disable: Disables automatica removing
of the failing units.
At next boot
Enable
Degraded Server Boot Policy
Specify the boot policy for the
degraded server.
Boot
Not-Boot
At next boot
Boot
FRB2 Monitoring
Enable or disable the boot monitoring
feature (FRB2 phase) for the server
(hardware and BIOS). If Enabled, Hard
Reset is performed automatically when
bootup failed.
Disable
Enable
Immediate
Enable
POST Monitoring
Enable or disable the boot monitoring
feature (POST phase) for the server
(hardware and BIOS).
If Enabled, Hard Reset is performed
automatically when bootup failed.
Immediate
Enable
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide
371

Table of Contents

Related product manuals