7. Using Remote Management
Chapter 3 Setup
Item Description When applied
Default
value(*1)
Disable
Enable
Boot Monitoring
Enable or disable the boot monitoring
feature of OS. If Enabled, Hard Reset
is performed automatically when
bootup failed.
Disable
Enable
Immediate
Disable
Monitoring time: 1 to 60 minutes
Immediate
1 (*3)
OpROM Monitoring
Enable or disable the boot monitoring
feature (OpROM boot phase) for the
server (hardware and BIOS). If
Enabled, Hard Reset is performed
automatically when bootup failed.
Disable
Enable
Immediate Disable
Failure Flow Monitoring
Enable or disable the feature to monitor
fault processing performed at
occurrence of failure.
Disable
Enable
Immediate
Disable
Monitoring time: 1 to 60 minutes
Immediate
30 (*3)
Shutdown Monitoring
Enable or disable monitoring feature of
server shutdown. When Enabled,
forcibly shuts down the server if normal
shutdown fails.
Disable
Enable
Immediate Enable
Monitoring time: 1 to 60 minutes
Immediate
10 (*3)
Diagnostics(*2)
Periodic Diagnosis(*2)
Enable or disable periodic diagnosis for
spare hardware component.
Disable
Enable
Immediate
Enable
Configuration
Master Clock Module (*2)
Specify whether the master clock is
assigned to Primary CLK (the youngest
number) or Secondary CLK.
Clock1
Clock2
At DC OFF:
Immediate
Other than DC
OFF: At next boot
Clock1
Spare Memory Configuration
Mode (*2)
Select Static or Dynamic for mode to
configure memory.
Static
Dynamic
At next boot
Static
Spare PCIe Configuration Mode
Select Static or Dynamic for mode to
configure PCIe card. (*1)
Static
Dynamic
At next boot Static
(*1) Factory-set value.
(*2) Displayed only when selectable dependig on server model.
(*3) If changed from Disable to Enable, Monitoring time returns to the default value.