PROGRAM MENU
Program: Select a program by entering the program number and confirm by pressing ENTER.
Priority: Priority determines the order in which programs will take place. If start time is the same, higher
priority programs come first. Higher priority programs do not stop currently operative programs.
If start time and priority are the same, irrigation programs with a lower number are executed first. Priority
ranges are between 0 and 15, 15 being the highest (See NMC-Pro Irrigation Part 2 > Priority specifications
for further information).
Const / Daily / Cond. / Rad Sum / VPD Sum:
CONST.: Increase or decrease the amount of water for all valves included in this program. 0% means
the quantities will be as specified in the Water Run Time program, 100% will be twice the amount and
50% will be half the amount specified in the Water Run Time Program. To decrease enter the required
percentage of change, press the +/- key and confirm with the ENTER key. The percentage of change is
active until you specify otherwise.
DAILY: Increase or decrease the amount of water for all valves included in this program. 0% means the
quantities will be as specified in the Water Run Time program, 100% will be twice the amount and
50% will be half the amount specified in the Water Run Time Program.
To decrease, enter the required percentage of change, press +/- key and confirm with the ENTER key.
The percentage of change will be active only for the present day and will change automatically back to
zero on End Day time.
Note: CONST. % and DAILY % does not change Quantity / time of water before and water after settings, nor
dosing quantities.
Note: When setting watering program and using 'Spread' the percentage affects not only the water but also the
dosing.
Cond.: Specify whether the Condition program can trigger irrigations, and choose a Condition program
to start/stop irrigations. Irrigations will be started and stopped according to the settings of the relevant
Condition program (see Ext. Condition, page 68, for additional information). If irrigation is not triggered
due to Condition program until Max time has elapsed irrigation will be performed due to Max time.
When choosing Condition, the screen will be split in two. To view the day sequence, press the Down
arrow when the cursor is placed on the bottom of the screen.
The Condition program has the third priority after active irrigation and uncompleted irrigation (See NMC-
Pro Irrigation Part 2 > Priority specifications for further information).

Table of Contents

Other manuals for Netafim nmc-pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Netafim nmc-pro and is the answer not in the manual?

Netafim nmc-pro Specifications

General IconGeneral
BrandNetafim
Modelnmc-pro
CategoryController
LanguageEnglish

Related product manuals