26
4. Connections
Digitax SF Instruction Manual
5. Descriptions of CN1 Connector Signals
Pin No.
4
Interface Circuit
PI(page 45) Control Mode
Signal Description P S T
SVON
Servo ON
Open
Turns the servo OFF.
Close
Turns the servo ON.
dif.
24
5
i/o
v
ol
t
i/o
v
ol
t
Pin No.
5
Interface Circuit
PI(page 45) Control Mode
Signal Description P S T
RESET
Alarm Reset
Close
Resets an alarm.
TIP
Be sure to turn off this signal after alarm reset execution.
Encoder-, product code-, and system- alarms are not reset
by this signal.
You must cycle control power of the drive.
dif.
24
5
v
ol
t
i/o
v
ol
t
RESET/PCLR
Alarm Clear / Position
Error Counter Clear
Close
Clears Alarm and Error counter.
i/o
Related parameters
No. 67.3

Table of Contents