45
Digitax SF Instruction Manual
Tuning
7
4. Using Digitax SF Connect to Measure Vibration Frequency (FFT)
7. Tuning
4.
Using Digitax SF Connect to Measure Vibration Frequency (FFT)
Click on the icon for the lter that you want
to set�
Up to four levels of the position command filters and
three levels of torque command lters are available�
Set the lter parameters�
For the notch filter, enter the vibration frequency
measured�
Click on
Waveform
monitor
to return to the waveform
monitor�
The lter that you just set will be shown on the list�
11
Unchecking the check box will switch the effect of the
filter ON/OFF
Switch on to verify the lter eect� Switching o will not
lose the lter parameter�
Tip for Notch Filter Setup
When you are setting a notch filter, use the initial value for the notch width and check the effect first�
After setting the notch filter, start the equipment, verify the filter effect, and lower the notch frequency
gradually� Measure the waveforms to find the best filter conditions such as frequency, width, and depth�
The notch frequency varies depending on the equipment
8
9
10
11