Table 3-6 describes the System Characteristics screen fields.
Table 3-6. System Characteristics screen fields
Field Description
MAC Address
The MAC address of the BayStack 350 switch.
Reset Count
A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.
Default 1
Range 0 to 2
32
-1
Last Reset Type
A read-only field that indicates the last type of reset.
Default Power Cycle
Range Power Cycle, Software Download, Management Reset,
Management Factory Reset
sysDescr
A read-only field that specifies the hardware and software version.
sysObjectID
A read-only field that provides a unique identification of the switch, which contains the
vendor’s private enterprise number.
sysUpTime
A read-only field that shows the length of time since the last reset. Note that this field
is updated when the screen is redisplayed.
sysServices
A read-only field that indicates the switch’s physical and data link layer functionality.
sysContact
The name and phone number of the person responsible for the switch.
Default Zero-length string
Range Any ASCII string of up to 56 printable characters
1
1
Although this field can be set to up to 255 characters from a Network Management Station (NMS), only 56 characters
are displayed on the console terminal.
sysName
A name that uniquely identifies the switch.
Default Zero-length string
Range Any ASCII string of up to 56 printable characters
1
sysLocation
The physical location of the switch.
Default Zero-length string
Range Any ASCII string of up to 56 printable characters