45584901TH Rev.1
5-51 /
Oki Data CONFIDENTIAL
[F106_3] ADI-HDD error: ADI authentication Admin Password generation error
Classification Error item
Other service call ADI-HDD error: The generation of ADI authentication Admin Password
fails.
Check item Measures
Setting Reinstall the system firmware.
Reinstall the system software.
[F106_4] ADI-HDD error: Authentication random number generation error
Classification Error item
Other service call ADI-HDD error: The generation of a random number for authentication
data fails.
Check item Measures
Setting Reinstall the system firmware.
Reinstall the system software.
[F106_5] ADI-HDD error: Authentication data transmission error
Classification Error item
Other service call ADI-HDD error: The transmission of authentication data fails.
Check item Measures
Setting Reinstall the system firmware.
Reinstall the system software.
• IncasethiserroroccurredafterreturningSRAMdataforSRAM
cloning:
Copy the ADI-HDD encryption key from FROM to SRAM.
1.Starttheequipmentinthe3Cmode:[3]+[C]+[POWER]
2.Theauthenticationmenuisdisplayed.Press[OK].(Notrequiredinthe
default setting)
3.Select"5.KeyBackupRestore"andthenpressthe[START]button.
4.Select"6.ADIKeyFROMtoSRAM"andthenpressthe[START]
button.
5.Aftertherestoringoftheencryptionkeyhascompleted,"Operation
Complete" is displayed.
6.Aftertheoperationhascompleted,shutdowntheequipmentby
pressingthe[POWER]button.