45584901TH Rev.1
11-171 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System Wireless
LAN
9649 WirelessLAN
setting
2 1-2 NIC SetswhetherthewirelessLANconnectionisenabledor
disabled.
1: Enabled
2: Disabled
12
08 Setting
mode
System Network DHCP 9694 Enabling server's IP
addressacquiredby
DHCP
1 1-2 - DNS domain name Option (15) DNS domain name of the
client
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System User
interface
9698 Color mode
notification setting
at ACS
0 0-1 SYS 0: Color
1: Black
1
08 Setting
Mode
System Mainte-
nance
General 9700 Service technician
telephone number
0 32 digits SYS A telephone number can be entered up to 32 digits. Use
the [MONITOR/PAUSE] button to enter a hyphen(-).
11
08 Setting
mode
System User
interface
9702 Automatic
calibration
disclosure level
1 0-2 SYS Sets the disclosing level of automatic calibration.
0: Service technician
1: Administrator
2: User
1
08 Setting
Mode
System Mainte-
nance
General 9703 Error history display - - SYS Displays the latest 20 errors data 2
08 Setting
mode
System Network Scanning 9709 Default data saving
directory of "Scan to
File"
0 0-2 SYS 0:Localdirectory
1: REMOTE 1
2: REMOTE 2
1
08 Setting
Mode
System Mainte-
nance
RDMS General 9710 Remote-controlled
service function
2 0-2 SYS 0:Valid(Remote-controlledserver)
1:Valid(L2)
2: Invalid
1
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9711 Remote-controlled
serviceURLsetting
- - SYS Maximum 256 letters 11
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9715 Initially-registered
serverURLsetting
Refer
to
contents
- SYS Maximum 256 letters
<Default value>
https://device.mfp- support.com:443/device/firstregist.
ashx
11
08 Setting
mode
System Mainte-
nance
(Remote)
RDMS 9718 Short time interval
setting of recovery
from Emergency
Mode
24 1-48 SYS Sets the time interval to recover from the Emergency
Mode to the Normal Mode.
(Unit: Hour)
1
08 Setting
mode
System Mainte-
nance
RDMS 9719 Short time
interval setting of
Emergency Mode
60 30-360 SYS Unit: Minute 1
08 Setting
Mode
System Mainte-
nance
RDMS General 9723 Periodical polling
timing
1430 0-2359 SYS (Hour/Hour/Minute/Minute)
0 (0:00) to 2359 (23:59)
1